Value of nocturnal oxygen saturation as a screening test for sleep apnoea.

The sensitivity and specificity of overnight recording of arterial oxygen saturation (SaO2) in routine clinical practice was evaluated in 41 subjects who were being investigated for possible sleep apnoea-hypopnoea syndrome. SaO2 was measured with an ear probe oximeter (Biox IIa) and chart recorder d...