Bilateral diaphragm paralysis after cardiac surgery with topical hypothermia.

Bilateral diaphragm paralysis is a rare but important complication of open heart surgery. Two cases were found among 360 prospectively studied patients undergoing open heart surgery during one year. Both patients had insulin dependent diabetes with peripheral neuropathy and this may have contributed...