Pulmonary deposition of nebulised pentamidine isethionate: effect of nebuliser type, dose, and volume of fill.
An estimate of the absolute pulmonary deposition of nebulised pentamidine isethionate was obtained in nine patients with AIDS. Two nebuliser systems were compared, System 22 Mizer (Medic-Aid) and Respirgard II (Marquest), with 50 and 150 mg doses of pentamidine in a 3 ml solution driven by an air fl...