Intubation Biomechanics: Laryngoscope Force and Cervical Spine Motion during Intubation in Cadavers—Cadavers vs. Patients, the Effect of Repeated Intubations, and the Effect of Type II Odontoid Fracture on C1-C2 Motion

INTRODUCTION: The aims of this study were to characterize: 1) cadaver intubation biomechanics, including the effect of repeated intubations; and 2) the relationship between intubation force and the motion of an injured cervical segment. METHODS: Fourteen cadavers were serially intubated using force-...

Fuld beskrivelse

Na minha lista:
Bibliografiske detaljer
Udgivet i:Anesthesiology
Main Authors: Hindman, Bradley J., From, Robert P., Fontes, Ricardo B., Traynelis, Vincent C., Todd, Michael M., Zimmerman, M. Bridget, Puttlitz, Christian M., Santoni, Brandon G.