Quality Assurance System Using Statistical Process Control: An Implementation for Image Cytometry

Aims: Optical technologies have shown some promise for improving the care of cervical neoplasia. We are currently evaluating fluorescence and reflectance spectroscopy and quantitative cyto‐histopathology for cervical neoplasia screening and diagnosis. Here we describe the establishment and applicati...

Full description

Saved in:
Bibliographic Details
Published in:Cell Oncol
Main Authors: Chiu, David, Guillaud, Martial, Cox, Dennis, Follen, Michele, MacAulay, Calum
Format: Artigo
Language:Inglês
Published: IOS Press 2004
Subjects:
Online Access:https://ncbi.nlm.nih.gov/pmc/articles/PMC4611122/
https://ncbi.nlm.nih.gov/pubmed/15371646
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1155/2004/794021
Tags: Add Tag
No Tags, Be the first to tag this record!