Addition of sodium metabisulphite to left atrial catheter infusates as a means of preventing bacterial colonisation of the catheter tip.

Sodium metabisulphite (SMBS) was added at a concentration of 0.05% to the dextrose-heparin solution used to flush left atrial catheters in one group of open-heart surgery patients. Two other groups of patients had left atrial catheters flushed with dextrose-heparin alone. Comparison of the isolation...