Loading...

Plasma concentrations of lignocaine during fibreoptic bronchoscopy.

Peak plasma concentrations of lignocaine were recorded in 41 patients receiving topically applied lignocaine for fiberoptic bronchoscopy. Adequate anaesthesia was achieved in all patients with an average dose per unit weight of 9.3 +/- 0.5 mg/kg (SEM) giving a mean peak plasma concentration of 2.9 +...

Fuld beskrivelse

Na minha lista:
Bibliografiske detaljer
Main Authors: Efthimiou, J, Higenbottam, T, Holt, D, Cochrane, G M
Format: Artigo
Sprog:Inglês
Udgivet: 1982
Fag:
Online adgang:https://ncbi.nlm.nih.gov/pmc/articles/PMC459249/
https://ncbi.nlm.nih.gov/pubmed/7071796