Loading...
Plasma concentrations of lignocaine during fibreoptic bronchoscopy.
Peak plasma concentrations of lignocaine were recorded in 41 patients receiving topically applied lignocaine for fiberoptic bronchoscopy. Adequate anaesthesia was achieved in all patients with an average dose per unit weight of 9.3 +/- 0.5 mg/kg (SEM) giving a mean peak plasma concentration of 2.9 +...
Na minha lista:
| Main Authors: | , , , |
|---|---|
| Format: | Artigo |
| Sprog: | Inglês |
| Udgivet: |
1982
|
| Fag: | |
| Online adgang: | https://ncbi.nlm.nih.gov/pmc/articles/PMC459249/ https://ncbi.nlm.nih.gov/pubmed/7071796 |
| Tags: |
Tilføj Tag
Ingen Tags, Vær først til at tagge denne postø!
|