Prosthetic mitral valve obstruction: role of real-time three-dimensional transesophageal echocardiography in diagnosis

Acute prosthetic valve thrombosis is a potentially serious complication with an incidence as high as 6% per patient-year for prostheses in the mitral position. Accurate diagnosis of the degree of obstruction and differentiation of pannus versus thrombus is critical in determination of the best mode...