Use of 100 kV versus 120 kV in computed tomography pulmonary angiography in the detection of pulmonary embolism: effect on radiation dose and image quality
OBJECTIVE: To determine the effective radiation dose and image quality resulting from 100 versus 120 kilovoltage (kV) protocols among patients referred for computed tomography pulmonary angiography (CTPA). METHODS: Sixty-six patients with clinical suspicion of pulmonary embolism (PE) were prospectiv...