A Single-Center Experience with Luminal Venous Cannulae Obstruction Caused by Clot Formation during Bypass
Our institution experienced two bypass cases from January through December 2011 in which venous return was significantly variable and at times poor. Luminal clot formation in the venous cannulae was found in each case postbypass. These events were captured and monitored through our institution’s Non...