Is Strain Elastography (IO-SE) Sufficient for Characterization of Liver Lesions before Surgical Resection—Or Is Contrast Enhanced Ultrasound (CEUS) Necessary?

AIM: To evaluate the diagnostic accuracy of IO-SE in comparison to IO-CEUS for the differentiation between malignant and benign liver lesions. MATERIAL AND METHODS: In a retrospective diagnostic study IO-CEUS and SE examinations of 49 liver lesions were evaluated and compared to histopathological ex...