Wird geladen...

Use of a 24 Gauge Intravenous Cannula for Minimally Invasive Trabeculectomy

We describe an innovative technique for performing standardized low cost glaucoma filtration surgery using a polytetrafluoroethylene (PTFE) intravenous cannula. The trocar of a 24 gauge (24G) PTFE intravenous cannula was used to create a trabeculectomy ostium and its tube was inserted under a partia...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:J Ophthalmic Vis Res
Hauptverfasser: Dada, Tanuj, Angmo, Dewang, Temkar, Shreyas, Sharma, Reetika
Format: Artigo
Sprache:Inglês
Veröffentlicht: Medknow Publications & Media Pvt Ltd 2015
Schlagworte:
Online Zugang:https://ncbi.nlm.nih.gov/pmc/articles/PMC4424726/
https://ncbi.nlm.nih.gov/pubmed/26005560
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.4103/2008-322X.156130