IN VITRO VALIDATION OF FINITE ELEMENT MODEL OF AAA HEMODYNAMICS INCORPORATING REALISTIC OUTLET BOUNDARY CONDITIONS

PURPOSE: To validate numerical simulations of flow and pressure in an abdominal aortic aneurysm (AAA) using phase-contrast MRI (PCMRI), and an in-vitro phantom under physiological flow and pressure conditions. MATERIALS AND METHODS: We constructed a 2-outlet physical flow phantom based on patient im...