In Vitro Validation of Finite Element Analysis of Blood Flow in Deformable Models

PURPOSE: To validate numerical simulations of flow and pressure incorporating deformable walls using in-vitro flow phantoms under physiological flow and pressure conditions. METHODS: We constructed two deformable flow phantoms mimicking a normal and a restricted thoracic aorta, and used a Windkessel...