Systematic Review of Patient-specific Instrumentation in Total Knee Arthroplasty: New but Not Improved

BACKGROUND: Patient-specific cutting blocks have been touted as a more efficient and reliable means of achieving neutral mechanical alignment during TKA with the proposed downstream effect of improved clinical outcomes. However, it is not clear to what degree published studies support these assumpti...