Whole Body Clearance of Norepinephrine. THE SIGNIFICANCE OF ARTERIAL SAMPLING AND OF SURGICAL STRESS

The whole body clearance of norepinephrine (NE) was measured in seven patients pre- and postoperatively. L[(3)H]NE was infused intravenously for 90 min and steady-state concentrations of L[(3)H]NE were measured at 75 and 90 min in both arterial and peripheral venous blood. Preoperatively, in the res...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Publicado no:J Clin Invest
Principais autores: Hilsted, Jannik, Christensen, Niels J., Madsbad, Sten
Formato: Artigo
Idioma:Inglês
Publicado em: American Society for Clinical Investigation 1983
Assuntos:
Acesso em linha:https://ncbi.nlm.nih.govhttps://pmc.ncbi.nlm.nih.gov/articles/PMC436897/
https://ncbi.nlm.nih.govhttps://pubmed.ncbi.nlm.nih.gov/6826720/
https://ncbi.nlm.nih.govhttps://doi.org/10.1172/JCI110794
Tags: Adicionar Tag