Flowtron foot-pumps for prevention of venous thromboembolism in total hip and knee replacement

INTRODUCTION: Mechanical prophylaxis with foot-pumps provides an interesting alternative to chemical agents in the prevention of venous thomboembolism following major orthopaedic surgery procedures. The aim of this prospective study was to assess efficacy and safety of the Flowtron(®) foot-pumps sys...