Carregant...
Artifactual microhemorrhage generated by SWI processing
PURPOSE: To report that artifactual microhemorrhages are introduced by the 2D homodyne filtering method of generating susceptibility weighted images (SWI) when open-ended fringelines (OEF) are present in phase data. MATERIALS AND METHODS: SWI data from 28 traumatic brain injury (TBI) patients was ob...
Guardat en:
| Publicat a: | J Magn Reson Imaging |
|---|---|
| Autors principals: | , , , |
| Format: | Artigo |
| Idioma: | Inglês |
| Publicat: |
2014
|
| Matèries: | |
| Accés en línia: | https://ncbi.nlm.nih.gov/pmc/articles/PMC4336235/ https://ncbi.nlm.nih.gov/pubmed/25143262 https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1002/jmri.24728 |