Chargement en cours...

Pulsatile motion of trabecular meshwork in a patient with iris cyst by phase-sensitive optical coherence tomography: a case report

A 45-year-old man was diagnosed with a 3 mm × 3 mm iris cyst located at 9 o’clock behind iris and protruding into temporal angle by slit lamp examination, gonioscopy, and ultrasound biomicroscopy (UBM). Phase-sensitive optical coherence tomography (PhS-OCT) was applied on this case for the quantitat...

Description complète

Enregistré dans:
Détails bibliographiques
Publié dans:Quant Imaging Med Surg
Auteurs principaux: Sun, Yi-Chen, Li, Peng, Johnstone, Murray, Wang, Ruikang K., Shen, Tueng T.