Measurement of Gas-Liquid Two-Phase Flow in Micro-Pipes by a Capacitance Sensor

A capacitance measurement system is developed for the measurement of gas-liquid two-phase flow in glass micro-pipes with inner diameters of 3.96, 2.65 and 1.56 mm, respectively. As a typical flow regime in a micro-pipe two-phase flow system, slug flow is chosen for this investigation. A capacitance...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Publicado no:Sensors (Basel)
Main Authors: Ji, Haifeng, Li, Huajun, Huang, Zhiyao, Wang, Baoliang, Li, Haiqing
Formato: Artigo
Idioma:Inglês
Publicado em: MDPI 2014
Assuntos:
Acesso em linha:https://ncbi.nlm.nih.gov/pmc/articles/PMC4299021/
https://ncbi.nlm.nih.gov/pubmed/25587879
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.3390/s141222431