Renal function, uraemia and early arteriovenous fistula failure

BACKGROUND: Guidance varies regarding the optimal timing of arteriovenous fistula (AVF) creation. The aim of this study was to evaluate the association between uraemia, haemodialysis and early AVF failure. METHODS: Immunoblotting and cell proliferation assays were performed on vascular smooth muscle...