Serial Changes of Neointimal Tissue after Everolimus-Eluting Stent Implantation in Porcine Coronary Artery: An Optical Coherence Tomography Analysis
Purposes. The serial changes in neointimal tissues were compared between everolimus-eluting stent (EES) and bare-metal stent (BMS) in the porcine coronary artery using optical coherence tomography (OCT). Methods. Serial (1, 3, and 6 month follow-up after stent implantation) OCT examinations were per...