Analysis of mechanical strength to fixing the femoral neck fracture in synthetic bone type Asnis

OBJECTIVE: To analyze the results of biomechanical assays of fixation of Pauwels type III femoral neck fracture in synthetic bone, using 7.5mm cannulated screws in inverted triangle formation, in relation to the control group. METHODS: Ten synthetic bones were used, from a domestic brand, divided in...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Main Authors: Freitas, Anderson, Lula, Welder Fernandes, de Oliveira, Jonathan Sampaio, Maciel, Rafael Almeida, Souto, Diogo Ranier de Macedo, Godinho, Patrick Fernandes
Formato: Artigo
Idioma:Inglês
Publicado em: Sociedade Brasileira de Ortopedia e Traumatologia 2014
Assuntos:
Acesso em linha:https://ncbi.nlm.nih.gov/pmc/articles/PMC4167045/
https://ncbi.nlm.nih.gov/pubmed/25246851
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1590/1413-78522014220400917