Continuous tracheal gas insufflation during protective mechanical ventilation in juvenile piglets with acute lung injury induced by endotoxin

BACKGROUND: Low tidal volume mechanical ventilation is difficult to correct hypoxemia, and prolonged inhalation of pure oxygen can lead to oxygen poisoning. We suggest that continuous tracheal gas insufflation (TGI) during protective mechanical ventilation could improve cardiopulmonary function in a...