A Pelvic Implant Orthosis in Rodents, for Spinal Cord Injury Rehabilitation, and for Brain Machine Interface Research: Construction, Surgical Implantation and Validation

BACKGROUND: Rodents are important model systems used to explore Spinal Cord Injury (SCI) and rehabilitation, and Brain Machine Interfaces. We present a new method to provide mechanical interaction for BMI and rehabilitation in rat models of SCI. NEW METHOD: We present the design and implantation pro...

Cijeli opis

Spremljeno u:
Bibliografski detalji
Glavni autori: Udoekwere, Ubong Ime, Oza, Chintan S., Giszter, Simon F.
Format: Artigo
Jezik:Inglês
Izdano: 2013
Teme:
Online pristup:https://ncbi.nlm.nih.gov/pmc/articles/PMC4065419/