Unreliability of aortic size index to predict risk of aortic dissection in a patient with Turner syndrome

Aortic size index (ASI) has been proposed as a reliable criterion to predict risk for aortic dissection in Turner syndrome with significant thresholds of 20-25 mm/m(2). We report a case of aortic arch dissection in a patient with Turner syndrome who, from the ASI thresholds proposed, was deemed to b...