Plate osteosynthesis of fractures of the shaft of the humerus: comparison of limited contact dynamic compression plates and locking compression plates
BACKGROUND: The aim of this retrospective study was to compare outcomes and complications of displaced fractures of the shaft of the humerus treated with limited-contact dynamic compression plates (LCDCPs) and locking compression plates (LCPs). MATERIALS AND METHODS: Two hundred and twelve patients...