Wird geladen...
An analysis of the use of hyperoxia for measuring venous cerebral blood volume: Comparison of the existing method with a new analysis approach
Hyperoxia is known to cause an increase in the blood oxygenation level dependent (BOLD) signal that is primarily localised to the venous vasculature. This contrast mechanism has been proposed as a way to measure venous cerebral blood volume (CBVv) without the need for more invasive contrast media. I...
Gespeichert in:
| Hauptverfasser: | , , , , |
|---|---|
| Format: | Artigo |
| Sprache: | Inglês |
| Veröffentlicht: |
2013
|
| Schlagworte: | |
| Online Zugang: | https://ncbi.nlm.nih.gov/pmc/articles/PMC4012834/ https://ncbi.nlm.nih.gov/pubmed/23370053 https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1016/j.neuroimage.2013.01.039 |
| Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|