Laparoscopic Repair of Morgagni Hernia Using Polyvinylidene Fluoride (PVDF) Mesh
We report the cases of two patients diagnosed with Morgagni hernia who presented with nonspecific abdominal symptoms. Both underwent laparoscopic surgery that used a dual-sided mesh, polyvinylidene fluoride (PVDF; Dynamesh IPOM®). The procedures were successful and both patients were discharged with...