Single anion-selective channels in basolateral membrane of a mammalian tight epithelium.

Basolateral membrane chloride permeability of surface cells from rabbit urinary bladder epithelium was studied using the patch-clamp technique. Two types of anion-selective channel were observed. One channel type showed inward rectification and had a conductance of 64 pS at-50 mV when bathed symmetr...