Measurement of SAR-induced temperature increase in a phantom and in vivo with comparison to numerical simulation
PURPOSE: Compare numerically-simulated and experimentally-measured temperature increase due to Specific energy Absorption Rate (SAR) from radiofrequency fields. METHODS: Temperature increase induced in both a phantom and in the human forearm when driving an adjacent circular surface coil was mapped...