Loading...

Day and Night Closed-Loop Control in Adults With Type 1 Diabetes: A comparison of two closed-loop algorithms driving continuous subcutaneous insulin infusion versus patient self-management

OBJECTIVE: To compare two validated closed-loop (CL) algorithms versus patient self-control with CSII in terms of glycemic control. RESEARCH DESIGN AND METHODS: This study was a multicenter, randomized, three-way crossover, open-label trial in 48 patients with type 1 diabetes mellitus for at least 6...

Fuld beskrivelse

Na minha lista:
Bibliografiske detaljer
Main Authors: Luijf, Yoeri M., DeVries, J. Hans, Zwinderman, Koos, Leelarathna, Lalantha, Nodale, Marianna, Caldwell, Karen, Kumareswaran, Kavita, Elleri, Daniela, Allen, Janet M., Wilinska, Malgorzata E., Evans, Mark L., Hovorka, Roman, Doll, Werner, Ellmerer, Martin, Mader, Julia K., Renard, Eric, Place, Jerome, Farret, Anne, Cobelli, Claudio, Del Favero, Simone, Dalla Man, Chiara, Avogaro, Angelo, Bruttomesso, Daniela, Filippi, Alessio, Scotton, Rachele, Magni, Lalo, Lanzola, Giordano, Di Palma, Federico, Soru, Paola, Toffanin, Chiara, De Nicolao, Giuseppe, Arnolds, Sabine, Benesch, Carsten, Heinemann, Lutz
Format: Artigo
Sprog:Inglês
Udgivet: American Diabetes Association 2013
Fag:
Online adgang:https://ncbi.nlm.nih.gov/pmc/articles/PMC3836152/
https://ncbi.nlm.nih.gov/pubmed/24170747
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.2337/dc12-1956
Tags: Tilføj Tag
Ingen Tags, Vær først til at tagge denne postø!