Caricamento...

Stability-indicating HPLC Method for Simultaneous Determination of Aspirin and Prasugrel

A simple, sensitive, specific, accurate, and stability-indicating reversed phase high performance liquid chromatographic method was developed for the simultaneous determination of aspirin and prasugrel, using a Kromasil 100 C(18) (150×4.6 mm, 5 μ) column and a mobile phase composed of acetonitrile:m...

Descrizione completa

Salvato in:
Dettagli Bibliografici
Autori principali: Patel, Shital M., Patel, C. N., Patel, V. B.
Natura: Artigo
Lingua:Inglês
Pubblicazione: Medknow Publications & Media Pvt Ltd 2013
Soggetti:
Accesso online:https://ncbi.nlm.nih.gov/pmc/articles/PMC3831722/
https://ncbi.nlm.nih.gov/pubmed/24302795
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.4103/0250-474X.119816