T(1) Estimation for Aqueous Iron Oxide Nanoparticle Suspensions Using a Variable Flip Angle SWIFT Sequence
PURPOSE: T(1) quantification of contrast agents, such as super-paramagnetic iron oxide (SPIO) nanoparticles, is a challenging but important task inherent to many in vivo applications in magnetic resonance imaging (MRI). In this work, a sweep imaging with Fourier transformation using variable flip an...