Cement Embolism into the Venous System after Pedicle Screw Fixation: Case Report, Literature Review, and Prevention Tips

The strength of pedicle screws attachment to the vertebrae is an important factor affecting their motion resistance and long term performance. Low bone quality, e.g. in osteopenic patients, keeps the screw bone interface at risk for subsidence and dislocation. In such cases, bone cement could be use...