Automation of a Hemagglutination-Inhibition Test for Parainfluenza 3 Antibodies in Bovine Sera

An automated hemagglutination-inhibition (HI) test for the “shipping fever” strain (SF-4) of parainfluenza 3 antibody in bovine sera was developed and compared to manual tube and microtiter test procedures. The automated system operating at 60 samples per hr provided the most test results per specif...