A carregar...

Implementation, reliability testing, and compliance monitoring of the Confusion Assessment Method for the Intensive Care Unit (CAM-ICU) in trauma patients

OBJECTIVE: To implement delirium monitoring, test reliability, and monitor compliance of performing the Confusion Assessment Method for the Intensive Care Unit (CAM-ICU) in trauma patients. DESIGN AND SETTING: Prospective, observational study in a Level 1 trauma unit of a tertiary care, university-b...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Main Authors: Soja, Stacie L., Pandharipande, Pratik P., Fleming, Sloan B., Cotton, Bryan A., Miller, Leanna R., Weaver, Stefanija G., Lee, Byron T., Ely, E. Wesley
Formato: Artigo
Idioma:Inglês
Publicado em: 2008
Assuntos:
Acesso em linha:https://ncbi.nlm.nih.gov/pmc/articles/PMC3773486/
https://ncbi.nlm.nih.gov/pubmed/18297270
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1007/s00134-008-1031-x
Tags: Adicionar Tag
Sem tags, seja o primeiro a adicionar uma tag!