Method for the Preservation of Diagnostic Sera for Field and Laboratory Work

Paper discs impregnated with antiserum, lyophilized, and stored at temperatures ranging from −21 to 33 C have yielded potent and specific reagents when rehydrated 370 days later. Applications are discussed.