Carregant...

Inter- and Intra-Operator Variability in the Reading of Indirect Immunofluorescence Assays for the Serological Diagnosis of Scrub Typhus and Murine Typhus

Inter- and intra-observer variation was examined among six microscopists who read 50 scrub typhus (ST) and murine typhus (MT) indirect immunofluorescence assay (IFA) immunoglobulin M (IgM) slides. Inter-observer agreement was moderate (κ = 0.45) for MT and fair (κ = 0.32) for ST, and was significant...

Descripció completa

Guardat en:
Dades bibliogràfiques
Autors principals: Phetsouvanh, Rattanaphone, Thojaikong, Thaksinaporn, Phoumin, Phonlavanh, Sibounheuang, Bountoy, Phommasone, Koukeo, Chansamouth, Vilada, Lee, Sue J., Newton, Paul N., Blacksell, Stuart D.
Format: Artigo
Idioma:Inglês
Publicat: The American Society of Tropical Medicine and Hygiene 2013
Matèries:
Accés en línia:https://ncbi.nlm.nih.gov/pmc/articles/PMC3752761/
https://ncbi.nlm.nih.gov/pubmed/23478577
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.4269/ajtmh.12-0325
Etiquetes: Afegir etiqueta
Sense etiquetes, Sigues el primer a etiquetar aquest registre!