Effect of vasopressin on electrical potential difference and chloride transport in mouse medullary thick ascending limb of Henle's loop.
Medullary thick ascending limbs of Henle's loop of the Swiss-Webster mouse were perfused in vitro with an isotonic perfusate and a Ringer's bathing medium. In five studies, addition of a supramaximal concentration of synthetic arginine vasopressin (AVP) to the bathing medium resulted in an...