High‐Sensitivity Cardiac Troponin T Compared With Standard Troponin T Testing on Emergency Department Admission: How Much Does It Add in Everyday Clinical Practice?

BACKGROUND: We compared high‐sensitivity cardiac troponin T (hs‐cTnT) and standard cTnT for acute myocardial infarction (AMI) diagnosis in everyday clinical practice of an emergency department (ED). METHODS AND RESULTS: cTnT was measured in 2384 consecutive patients (60±21 years, 52% female) on ED a...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Main Authors: Hammerer‐Lercher, Angelika, Ploner, Thomas, Neururer, Sabrina, Schratzberger, Peter, Griesmacher, Andrea, Pachinger, Otmar, Mair, Johannes
Formato: Artigo
Idioma:Inglês
Publicado em: Blackwell Publishing Ltd 2013
Assuntos:
Acesso em linha:https://ncbi.nlm.nih.gov/pmc/articles/PMC3698787/
https://ncbi.nlm.nih.gov/pubmed/23735897
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1161/JAHA.113.000204