Development and Validation of New RP-HPLC Method for the Determination of Dexrazoxane

A new sensitive, precise, rapid and linear RP-HPLC method was developed and validated for the determination of dexrazoxane in formulations and human serum samples. Good chromatographic separation of dexrazoxane was achieved by using Kromasil C(18) column. The system was operated at ambient temperatu...