Načítá se...

Aortic Valve Replacement Using Balloon Catheter for Thoracic Endovascular Aortic Repair to Patient with Calcified Aorta

A 79-year-old man was admitted to Samsung Changwon Hospital due to chest pain and dyspnea. The ejection fraction was 31% and mean pressure gradient between the left ventricle and aorta was 69.4 mmHg on echocardiography. Chest computed tomography showed severe calcification of the ascending aorta. Ao...

Celý popis

Uloženo v:
Podrobná bibliografie
Hlavní autoři: Kim, In Sook, Byun, Joung Hun, Yoo, Byung Ha, Kim, Han Yong, Hwang, Sang Won, Song, Yun Gyu
Médium: Artigo
Jazyk:Inglês
Vydáno: Korean Society for Thoracic and Cardiovascular Surgery 2013
Témata:
On-line přístup:https://ncbi.nlm.nih.gov/pmc/articles/PMC3680608/
https://ncbi.nlm.nih.gov/pubmed/23772410
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.5090/kjtcs.2013.46.3.212