Radial artery pseudoaneurysm managed by prolonged ultrasound-guided compression repair and aided by interval application of compression device

We report a case of a right radial pseudoaneurysm due to assault. The pseudoaneurysm was treated successfully with prolonged ultrasound-guided compression for more than 300 minutes over multiple sittings coupled with the use of a compression device. We believe that if initial compression fails, a pr...