Clinical Results and Problems of Percutaneous Transluminal Angioplasty and Stenting for Extracranial Internal Carotid Stenoses: Is the Blocking Balloon Catheter System Useful for Prevention of Distal Embolism?

110 patients with extracranial ICA stenosis were treated by PTA or stenting. In 21 of 55 cases of only PTA and in 40 of 55 cases of stenting, we used our blocking balloon systems to prevent distal embolism. The morbidity and the mortality rates were 5.4% and 0%, respectively. There was only one embo...