A carregar...
Vertebral body compression fracture after removal of pedicle screws: a report of two cases
While the risks of pedicle screw insertion are well established, there is a paucity of reports on complications associated with implant removal. We report two cases of acute osteoporotic vertebral compression fractures of the instrumented vertebral body adjacent to the fractured vertebra due to remo...