A carregar...

PHILOS humerus plate for a distal tibial fracture

This report discusses the use of an alternative implant in the emergency fixation of a distal tibial fracture. We planned to fix the shear-type medial malleolar fracture in a closed, tri-malleolar fracture with a locking distal tibial plate. Intra-operatively, it was noted that the required plate wa...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Main Authors: Twaij, Haider, Damany, Dev
Formato: Artigo
Idioma:Inglês
Publicado em: Oxford University Press 2013
Assuntos:
Acesso em linha:https://ncbi.nlm.nih.gov/pmc/articles/PMC3578666/
https://ncbi.nlm.nih.gov/pubmed/24963933
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1093/jscr/rjs036