Rotator Cuff Integrity Correlates With Clinical and Functional Results at a Minimum 16 Years After Open Repair

BACKGROUND: Recurrent or persistent defects in the rotator cuff after its repair are common. Short- and medium-term surveys have revealed, after open repair, patients with an intact rotator cuff have increased function and ROM. However, no long-term studies have verified cuff integrity on MR arthrog...

Descripció completa

Guardat en:
Dades bibliogràfiques
Autors principals: Vastamäki, Martti, Lohman, Martina, Borgmästars, Niclas
Format: Artigo
Idioma:Inglês
Publicat: Springer-Verlag 2012
Matèries:
Accés en línia:https://ncbi.nlm.nih.gov/pmc/articles/PMC3549157/
https://ncbi.nlm.nih.gov/pubmed/22895686
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1007/s11999-012-2494-1