Código QR

Kinetic parameters for acetylcholine interaction in intact neuromuscular junction.

The dependency of miniature endplate current (mepc) rise time upon mepc amplitude and acetylcholine receptor site density was measured in lizard intercostal muscles and used to fit the rate constants in a simple kinetic scheme. The kinetic scheme included diffusion, two-step sequential binding of ac...

Descrición completa

Gardado en:
Detalles Bibliográficos
Publicado en:Proc Natl Acad Sci U S A
Principais autores: Land, B R, Salpeter, E E, Salpeter, M M
Formato: Artigo
Idioma:Inglês
Publicado: National Academy of Sciences 1981
Assuntos:
Acceso en liña:https://ncbi.nlm.nih.govhttps://pmc.ncbi.nlm.nih.gov/articles/PMC349224/
https://ncbi.nlm.nih.govhttps://pubmed.ncbi.nlm.nih.gov/6947281/
https://ncbi.nlm.nih.govhttps://doi.org/10.1073/pnas.78.11.7200
Tags: Engadir etiqueta
Sen Etiquetas, Sexa o primeiro en etiquetar este rexistro!