Llwytho...
Cyclic Fatigue Resistance and Fractographic Analysis of Race and Protaper Rotary NiTi Instruments
INTRODUCTION: This study investigated the fatigue and fracture modes of RaCe and ProTaper rotary instruments. MATERIALS AND METHODS: Fatigue resistance was evaluated by rotating the files 30° or 60° and with 2 or 5mm radius of curvature. RaCe taper 06 size 25 and ProTaper F1 files (n=40) were used....
Wedi'i Gadw mewn:
| Prif Awduron: | , , , , , |
|---|---|
| Fformat: | Artigo |
| Iaith: | Inglês |
| Cyhoeddwyd: |
Iranian Center for Endodontic Research
2011
|
| Pynciau: | |
| Mynediad Ar-lein: | https://ncbi.nlm.nih.gov/pmc/articles/PMC3487508/ https://ncbi.nlm.nih.gov/pubmed/23130057 |
| Tagiau: |
Ychwanegu Tag
Dim Tagiau, Byddwch y cyntaf i dagio'r cofnod hwn!
|